Alternatively called the EIA/TIA-449, the RS-449 is short for Recommended Standard-449. It is a data standard that specifies the functional and mechanical characteristics of the interconnection between DTE (data terminal equipment) and complying EIA (Electronic Industries Alliance) electronic standards RS-422 and RS-423. The RS-449 standard is commonly found in data network communication equipment. Below is a layout of the 37-pin configuration for the RS-449. It starts with pin 1, which is located at the top-left corner of the connector.
Pin | Signal | Source |
---|---|---|
1 | Shield | Common |
2 | Signal rate indicator | DTE |
3 | Unassigned | Unassigned |
4 | Send data | DTE |
5 | Send timing | DCE |
6 | Received data | DCE |
7 | Request to send | DTE |
8 | Receive timing | DCE |
9 | Clear to send | DCE |
10 | Local loopback | DTE |
11 | Data mode | DCE |
12 | Terminal ready | DTE |
13 | Receiver ready | DCE |
14 | Remote loopback | DTE |
15 | Incoming call | DCE |
16 | Select frequency | DTE |
17 | Terminal timing | DTE |
18 | Test mode | DCE |
19 | Signal ground | Common |
20 | Receive common | Common |
21 | Unassigned | Unassigned |
22 | Send data | Return |
23 | Send timing | Return |
24 | Receive data | Return |
25 | Request to send | Return |
26 | Receive timing | Return |
27 | Clear to send | Return |
28 | Terminal in service | DTE |
29 | Data mode | Return |
30 | Terminal ready | Return |
31 | Receiver ready | Return |
32 | Select standby | DTE |
33 | Signal quality | DCE |
34 | New signal | DTE |
35 | Terminal timing | Return |
36 | Standby indicator | DCE |
37 | Send common | Common |